How this calculation works
Calibrate fixed-look one-sided canonical normal boundaries to a total crossing probability, with OBrien–Fleming-shaped or constant Pocock-shaped thresholds.
Corr(Zi,Zj)=√[min(ti,tj)/max(ti,tj)]; bi=c/√ti or bi=c; choose c so P0(any Zi≥bi)=α.A worked example
Information fractions [0.33,0.67,1] and total one-sided α=0.025 give OB-shaped boundaries approximately [3.489371,2.448876,2.004491], with validated total null crossing probability 0.025.
Good to know
2–5 fixed canonical-normal looks, information fractions≥0.05 separated by≥0.05 and ending at1; one-sided α∈[0.005,0.2]. Common OB/Pocock-shaped boundary multiplier, not alpha spending. Gaussian density quadrature orders96/144, lower limit−10, validation tolerance3e−7; reject unresolved. No futility, power/sample-size optimization or adaptive schedule.
Reference: gsDesign authors: canonical normal sequential designs (opens in a new tab) ↗
Plan a finite sequence of looks
Repeatedly checking an ordinary Z test against the same single-look critical value can inflate the chance of a false positive. A group-sequential design instead specifies a finite set of information fractions and calibrates the probability of crossing any planned upper boundary. The interface concerns one-sided efficacy monitoring under a canonical joint-normal model.
Information fraction refers to statistical information relative to the final analysis, not necessarily calendar time or the fraction of enrolled participants. Different outcome types can accumulate information at different rates. The final fraction is one, and the preceding fractions must be chosen prospectively rather than moved after observing an unexpectedly promising interim result.
Compare this with the Sequential probability ratio test calculator for Bernoulli trials. Calibrate a finite planned-look normal test to a total type I error; an indefinite Bernoulli likelihood-ratio test uses a different experiment and stopping rule.
Use the canonical correlation structure
Under the null model, every standardized Z statistic has variance one. Earlier and later statistics are correlated because they share information: the correlation between looks i and j is the square root of the smaller information fraction divided by the larger. Treating the looks as independent would calibrate a different experiment and generally give incorrect boundaries.
The equivalent Brownian-increment representation provides a Markov conditional distribution from one look to the next. This implementation propagates the density of paths that have remained below every previous boundary. Integrating that surviving density after the final look gives the no-crossing probability; subtracting it from one gives the overall one-sided type I error.
Choose the shape separately from calibration
The OBrien–Fleming-shaped option makes the Z boundary proportional to one over the square root of information fraction, demanding stronger standardized evidence early. The Pocock-shaped option uses a common Z boundary at every look. A common multiplier is solved numerically so that the complete planned sequence reaches the entered total alpha.
These are fixed-look shape calibrations, not implementations of a named alpha-spending function. An alpha-spending design can react to different actual information times in ways this fixed schedule does not. The page therefore states both the chosen shape and the exact entered fractions, rather than using a familiar design name to imply unsupported flexibility.
Follow the three-look example
The default information fractions are 0.33, 0.67 and 1, with total one-sided alpha 0.025. Calibrating the OBrien–Fleming-shaped boundaries gives approximately 3.489371, 2.448876 and 2.004491. The final threshold is slightly higher than the ordinary single-look 0.025 upper-tail critical value because earlier opportunities to reject also consume error probability.
Cumulative null crossing probabilities are approximately 0.000242, 0.007263 and 0.025. Their successive differences describe first crossing at each look. These are not marginal normal tails at the individual boundaries, because a path that crossed earlier has already stopped and cannot be counted again as a first crossing at a later analysis.
Check numerical integration explicitly
Gaussian quadrature integrates the surviving density on a sufficiently wide finite lower-tail domain. Calibration uses one quadrature order, followed by a higher-order evaluation of the same boundaries. The reported difference checks that numerical integration error is small relative to the displayed total crossing probability rather than assuming that convergence of a boundary search proves integration accuracy.
The lower tail is truncated at minus ten standard deviations, whose missing normal probability is negligible for the stated tolerance. Very closely spaced information fractions can make conditional densities narrow and difficult to resolve on a global quadrature grid. The interface consequently requires at least 0.05 separation and rejects unresolved quadrature rather than displaying an unvalidated error-control claim.
Keep stopping rules and power separate
An upper-boundary crossing supplies the rejection event for this defined one-sided design. The tool does not construct a lower futility boundary, estimate conditional power, calculate the required final sample size or optimize expected duration under alternatives. Adding any of those features would require a more complete specification of operating characteristics and stopping conventions.
Data-dependent changes to the planned schedule, unblinded sample-size adjustments or switching the testing direction are not licensed by these numbers. The reported null crossing probability applies to the canonical model and entered stopping rule. It does not demonstrate that an application satisfies normal approximations, information estimation assumptions, independent increments or the relevant study-governance requirements.
Record the design inputs with the result
Two to five information fractions are supported, starting at or above 0.05, separated by at least 0.05 and ending at one. Total one-sided alpha must lie between 0.005 and 0.2. The output includes every boundary, the common multiplier, cumulative and first-crossing probabilities and the quadrature comparison used to validate the calibration.
The static example graph depicts the planned thresholds rather than a simulated successful trial. Preserve the fractions and shape with any reported critical values so that the design can be reproduced. For practical study planning, use specialist sequential-design software and appropriate scientific review when power, futility, nuisance parameters, adaptation or other features extend beyond this bounded calculation.
A few questions, answered
Is alpha entered separately at every look?
No. The entered alpha is the probability of crossing any planned upper boundary under the null. Calibration accounts for correlation and repeated opportunities to reject.
Are these alpha-spending boundaries?
No. They use fixed OBrien–Fleming-like or constant Pocock-like shapes with a common multiplier calibrated for the entered schedule; adaptive alpha spending is not implemented.
Why is the final OB-shaped boundary above 1.96?
Earlier looks also create rejection opportunities. At total one-sided alpha 0.025, the final threshold must account for those earlier crossings.
Can I move the information times after seeing results?
The reported calibration assumes the entered planned fixed schedule and canonical normal model. Data-dependent changes or adaptations require their own valid sequential-design analysis.