Science & engineering

Integrated reaction order fit calculator

Compare zero-, first- and second-order integrated linear fits with original-concentration residuals, explicit transform limitations and a selected fitted curve.

Your numbers

No thousands separators; use the units stated in the label

Calculated on your device. Your inputs aren’t sent to us.

Your result

Ready when you are

Enter your inputs and select Calculate.

Try it, understand it

Explore the result

Regress each standard integrated transform against the same increasing time series. Convert fitted values back to concentration, report original-scale residuals and compare models without claiming a reaction mechanism from R².

Worked example comparison
ExampleOutputWhat to notice
Worked exampleSelected integrated-model rate constant0.5The illustrated concentrations follow C = 10 exp(−0.5 t). The selected first-order transform is linear with slope −0.5, so its fitted rate constant is 0.5 per entered time unit.
View the zero-order fitSelected integrated-model rate constant2.569261The graph changes while all three residual comparisons remain available.
Constant concentrationsSelected integrated-model rate constant-0Fitted k is zero and centered transformed R² is labeled undefined.

Check your understanding

Can I choose order just by the largest transformed R²?

Not reliably; transforms change error weighting and do not prove mechanism.

Are constant responses given R² = 1?

No, centered R² is undefined for constant response.

Behind the numbers

How this calculation works

Regress each standard integrated transform against the same increasing time series. Convert fitted values back to concentration, report original-scale residuals and compare models without claiming a reaction mechanism from R².

THE FORMULAFit C = a+bt, ln(C) = a+bt and 1/C = a+bt; k is −b for zero/first order and b for second order

A worked example

The illustrated concentrations follow C = 10 exp(−0.5 t). The selected first-order transform is linear with slope −0.5, so its fitted rate constant is 0.5 per entered time unit.

Good to know

Descriptive unweighted transformed regressions, not mechanistic proof. No replicate times, uncertainty weights, background concentration or nonlinear regression. Rate units depend on concentration/time basis and order.

Transforming changes the error emphasis

A least-squares line in concentration, logarithm and reciprocal concentration minimizes three different residual definitions. Their R² values are therefore not interchangeable measures of fit on the original concentration scale.

The page also calculates original-scale residuals and SSE where predictions remain positive and finite. Constant transformed responses have undefined centered R² rather than a claimed perfect fit.

Rate constants carry order-dependent units

For first order, k has reciprocal-time units. Zero order uses concentration per time, while second order uses reciprocal concentration per time.

The software does not silently convert the input’s unit conventions. Keep time and concentration units consistent when comparing a fitted constant with another source.

A linear pattern is not a unique mechanism

Several integrated models can look similar over a short or noisy interval. A high transformed R² alone does not identify an elementary step or demonstrate a causal chemical pathway.

Negative fitted k is retained and is not labeled ordinary decay. Nonphysical transformed predictions are exposed rather than silently clipped into positive concentration values.

Use the result with the next measurement

The Arrhenius two temperature rate calculator compares compatible rate constants at different temperatures. Establishing a consistent reaction-order and unit convention comes before that temperature comparison.

Descriptive unweighted transformed regressions, not mechanistic proof. No replicate times, uncertainty weights, background concentration or nonlinear regression. Rate units depend on concentration/time basis and order.

A few questions, answered

Can I choose order just by the largest transformed R²?

Not reliably; transforms change error weighting and do not prove mechanism.

Are constant responses given R² = 1?

No, centered R² is undefined for constant response.

Are negative fitted rate constants clipped?

No, their sign is retained and explained.

Find your calculator

Start typing to explore the library.