Advanced maths

SISO H infinity norm calculator for a stable rational transfer function

Find the maximum frequency-response magnitude of a small stable proper continuous-time SISO transfer function.

Your numbers

List constant coefficient first, then increasing powers of s.
List constant coefficient first, then increasing powers of s.

Calculated on your device. Your inputs aren’t sent to us.

Your result

Ready when you are

Enter your inputs and select Calculate.

Report an issue

Behind the numbers

How this calculation works

Find the maximum frequency-response magnitude of a small stable proper continuous-time SISO transfer function. Compare zero frequency, nonnegative stationary-frequency candidates and the high-frequency limit.

THE FORMULA||G||∞=sup(ω≥0)|G(iω)|; x=ω², |G|²=N(x)/D(x), stationary numerator=N′D−ND′

A worked example

For G(s)=1/(s+1), |G(iω)|=1/√(1+ω²). Its maximum is1 atω=0, and its high-frequency limit is0.

Good to know

Real ascending coefficients; stable denominator degree1–4 and proper numerator. Stability is required of the supplied denominator; no unstable-cancellation recovery. Numerical stationary-root isolation and floating magnitude evaluation, not formal interval certification. Reject excessive root bounds and poorly scaled cases. Continuous SISO only, no discrete/MIMO or H2 norm.

Measure the largest sinusoidal gain

The H infinity norm of a stable continuous-time single-input single-output system is the supremum of its frequency-response magnitude. It asks for the largest steady sinusoidal amplification across all frequencies, rather than an average gain, a response at one chosen frequency, or the energy of an impulse response.

Stability and properness are part of this calculator's input contract. The supplied denominator must have every pole strictly in the left half-plane, and the numerator degree cannot exceed its degree. A transfer expression containing an unstable common factor is rejected rather than silently interpreted after an uncertain floating-point cancellation.

The first-order gain decreases from one1ω|G(iω)| = 1/√(1+ω²)
Scroll across to see the full diagram.
The default transfer has its maximum at zero frequency and tends to zero as frequency grows.

Compare this with the Matrix resolvent and spectral projector calculator. Find the largest frequency-response magnitude of a stable continuous transfer function,not evaluate a resolvent at one supplied frequency.

Enter coefficients in ascending order

Write the constant term first, followed by coefficients of increasing powers of s. For s squared plus three s plus two, enter2,3,1. Preserve zero coefficients when a power is absent. This convention differs from libraries that expect the highest power first, so check any copied coefficient vector before calculating.

The denominator degree is limited to four, making a bounded real stability test and polynomial stationary-point analysis practical. Multiplying numerator and denominator by the same nonzero scale leaves the mathematical transfer function unchanged, but extreme coefficient scales can still harm floating arithmetic. Rescale equivalent expressions if numerical range checks reject the input.

Turn frequency search into a polynomial problem

For real coefficients, the squared magnitude at i omega can be written as a rational function of x equal to omega squared. Separating even and odd polynomial parts makes both its numerator and denominator real polynomials in x. This removes explicit complex arithmetic from the stationary-frequency calculation while retaining the entire nonnegative frequency axis.

Differentiate that rational function. Its finite stationary candidates are nonnegative roots of N prime times D minus N times D prime. The calculator numerically isolates those real roots, converts each x back to a frequency, and evaluates the original squared-magnitude ratio. Repeated or nearly vanishing stationary polynomials require special attention to scaling.

Include both ends of the frequency range

A maximum can occur at zero frequency, at a positive stationary frequency, or as frequency tends to infinity. The calculation explicitly compares all three possibilities. A strictly proper transfer function has high-frequency limit zero; an equal-degree proper transfer function instead approaches the absolute ratio of its leading coefficients.

Ignoring the infinite-frequency limit could understate the norm for a transfer function with feedthrough. Ignoring zero frequency would miss the default first-order low-pass maximum. The result therefore reports the high-frequency limit and candidate list alongside the selected norm, making the comparison visible rather than presenting only an unexplained maximum value.

Check the first-order example analytically

For one divided by s plus one, substituting s equal to i omega gives magnitude squared one divided by one plus omega squared. This decreases throughout the nonnegative frequency range. Its derivative has no nonnegative zero, so the only relevant finite candidate is omega equal to zero.

The magnitude there is one, while the high-frequency limit is zero. The returned norm is therefore one at zero radians per unit time. Changing the pole from minus one to minus two while keeping numerator one halves the zero-frequency gain, illustrating why a stable denominator alone does not determine the norm without the numerator scaling.

Interpret peak frequency and numerical limits

The peak frequency is expressed in radians per unit time, consistent with the time scale implicit in s. A result labeled infinity means the supremum is approached at arbitrarily high frequency. It does not identify a finite resonant oscillation. Multiple frequencies can share the same maximum, while the output may display only one selected peak.

The root search uses floating coefficients, finite tolerances and a bounded polynomial root interval. It is not a rigorous enclosure of all candidate frequencies under arbitrary conditioning. Large root bounds or near-degenerate coefficient relationships can trigger rejection; such a rejection establishes no upper bound on the system norm and should prompt rescaling or a specialized numerical tool.

Use the norm in its proper setting

For stable linear systems, the norm is useful when comparing frequency-domain amplification and model-reduction error bounds. It does not by itself establish closed-loop robustness for an unspecified feedback connection or describe nonlinear saturation. Those questions require additional system structure and assumptions beyond the transfer function supplied to this calculation.

When validating a custom example, inspect frequency-response samples near every reported candidate and compare a case with a known analytic maximum. This helps detect coefficient-order and unit errors. Preserve the numerator, denominator and frequency convention when sharing a result, since the same bare coefficient numbers can describe a different system under another ordering convention.

A few questions, answered

Is this the H2 norm?

No. It maximizes frequency-response magnitude rather than integrating squared magnitude.

Why is infinity a possible peak?

A proper transfer with feedthrough can approach its largest magnitude at high frequency.

What coefficient order is used?

Enter the constant coefficient first, followed by ascending powers.

Is the answer formally certified?

No. Stationary roots and response magnitudes are computed numerically with bounded floating arithmetic.

Find your calculator